Laserfiche WebLink
L Y <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Aria 1672 Elev D 1 Builder Name: DRH Express Homes <br /> Street:j��pS� S t� t `#-!bT �`I Permit Office: (:4 <br /> City,State,Zip: Zephyrhills,FL, 33$�+ Q Permit Number: 7CS_Zv / 7 <br /> Owner: ` I]J Jurisdiction: 6 (� <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 286.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1672.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 334 <br /> a. U-Factor: Dbl,U=0.34 142.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.929 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> B. Floor Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.109 Total Proposed Modified Loads: 55.99 PASS <br /> Total Baseline Loads: 57.09 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0Z13$ <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. nrn '�•;- = '„ <br /> PREPARED BY: - Lmc J,M:• Before construction is completed ` <br /> DATE: 1-11- a this buildingwill be inspected for <br /> p c7 �� <br /> compliance with Section 553.908 ii <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. WME <br /> OWNER/AGENT: BUILDING OFF <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit'manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 8/19/2020 4:02 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />