Laserfiche WebLink
+ .wrightsoft, Manual S Compliance Report Date: <br /> Entire House ey: <br /> Progressive Air Systems, Inc Plan: Aria 1672 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Rroject Information <br /> For: DR Horton <br /> Lot 14 Blk 18 Silverado, Zephyrhills, FL <br /> -Cooling EqjApment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 20927 Btuh Entering coil DB: 77.2°F <br /> Outdoor design WB: 77.1 OF Latent gain: 3639 Btuh Entering coil WB: 63.6°F <br /> Indoor design DB: 75.0°F Total gain: 24566 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIItASHP <br /> Manufacturer: Carrier Model: CH14NB030+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23631 Btuh 113%of load <br /> Latent capacity: 3687 Btuh 101%of load <br /> Total capacity: 27319 Btuh 111%of load SHR: 87% <br /> Waiting Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 21693 Btuh Entering coil DB: 69.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: CH14NB030+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25624 Btuh 118%of load Capacity balance: 32 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 6.4 kW 101%of load Temp. rise: 20 OF <br /> Meets are all requirements of ACCA Manual S. <br /> wri htsoft° 2020-Aug-1916:03:37 <br /> 9 Right-Suite@ Universal 2017 17.0.21 RSU25554...soft Flles\DR Horton\Express\Aria 4EAB 1672.rup Calc=MJ8 House Front faces: S Page 1 <br />