My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-752
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-752
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 11:31:53 AM
Creation date
2/24/2022 11:31:51 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-752
Building Department - Name
DR HORTON
Address
35659 STELLA VAST DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - wrightsoft° Load Short Form Da <br /> Job: <br /> House By: <br /> Progressive Air Systems, Inc Plan: Aria 1672 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton <br /> Lot 14 Blk 18 Silverado, Zephyrhills, FL <br /> Design Information <br /> Htg Clg Infiltration <br /> Outside db(°F) 40 91 Method Simplified <br /> Inside db(°F) 70 75 Construction quality Semi-tight <br /> Design TD (OF) 30 16 Fireplaces 0 <br /> Daily range - L <br /> Inside humidity (%) 50 50 <br /> Moisture difference(gr/lb) 26 54 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NBO30 Cond CH14NBO30 <br /> AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh Co) 47OF Latent cooling 7500 Btuh <br /> Temperature rise 27 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.046 cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0.48 in H2O Static pressure 0.48 in H2O <br /> Space thermostat Load sensible heat ratio 0.85 <br /> Capacity balance point=32 OF <br /> Backup: <br /> In ut=6 kW Out ut=21934 Btuh 100 AFUE <br /> ROOM NAME Area Htg load Clg load Htg AVF Clg AVF <br /> (ft2) (Btuh) (Btuh) (cfm) (cfm) <br /> m bed 237 3521 2709 162 129 <br /> dining 183 3260 3677 150 176 <br /> great 275 3513 3405 162 163 <br /> wic 49 938 461 43 22 <br /> we 25 0 0 0 0 <br /> m bath 135 1895 1077 87 51. <br /> kitchen 146 187 2066 9 99 <br /> laundry 42 266 960 12 46 <br /> bed 3 154 1705 1984 79 95 <br /> foyer 125 1746 1610 81 77 <br /> bath 2 60 706 389 33 19 <br /> bed 2 166 3954 2590 182 124 <br /> a/c 14 0 0 0 0 <br /> hall 37 0 0 0 0 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 1 WI'1 F1t50fit" 2020-Aug-1916:03:37 <br /> Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> AWN ..soft Files\DR Horton\Express\Aria 4EAB 1672.rup Cale=MJ8 House Front faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.