My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-757
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-757
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 11:35:35 AM
Creation date
2/24/2022 11:35:34 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-757
Building Department - Name
DR HORTON
Address
7018 STEER BLADE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> D <br /> Q <br /> I. <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.-shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3o f the F.B.C. <br /> 3. Corripactiori test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All.property markers shall be uncovered'arid marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be met: <br /> 9; No electric, plumbing;mechanical, or.framing shall be covered without an inspection and <br /> . <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not beinstalled in a location where subject to mechanical damage unless <br /> protected by approved barriers. 1VI303:4 of the F:B.0 <br /> 12. Water heaters shall comply with section P607.3 of the FAIC. <br /> 13. Foundation supports for A/C-units shall be raised_ at least 3" above f nislied grade. M1308:1- <br /> 14. Return air in all bedrooms. F.B.-C. M1620:4 <br /> 15. Smoke.detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be iri accordance with R308A of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C: <br /> 18. ``Green gypsum.board" shall not be used as a backer'in showers or tubs. R702:4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are.required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will.be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit.to unit: This includes all <br /> underground:plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.