Laserfiche WebLink
21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016-N.E:C <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water'pipe insulation. <br /> Insulation for hot.water pipe-with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping:V.inch (19.1 mm)and larger in nominal diameter. <br /> Piping,serving more than:one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the:water'heater to a distribution manifold., <br /> .Piping located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25:Blower door test shall be provided before C.O: <br /> 26. A copy of the enerzy cacls shall be with permit at all times. <br /> 27. Copy of hal.insulation report shall be provided with permit before rinaL- <br /> 28. No fence,Pool or screen enclosure Is issued with This-hermit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C--Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />