Laserfiche WebLink
ACI RECEIVED <br /> BUI IDINQ SXSTEMS,LLC FEB 192019 <br /> February 12,2019 <br /> Ryman Construction of FL RYMAN CONSTRUCTION <br /> 36413 SR 54 --® <br /> Zephyrhills, FL 33541 <br /> RE: B18-9334 A-B <br /> Packaging Facility(2-13 Warehousing) <br /> Project Description-a=50x7O.67x22/26.17(1.0:12) b=65x100x20.75/26.17(1.0:12) <br /> Corner of Trump Place and Correia Drive <br /> Zephyrhills, FL 33541 <br /> To whom it may concern: <br /> This letter is to certify that the above referenced project and its components have been designed in general accordance with the <br /> code referenced AISC Steel Construction Manual and the code referenced AISI North America Specification for the Design of Cold- <br /> Formed Steel Structural Members,as well as the designated building code stipulated in the order documentation. <br /> Based on the requirements of the order documentation, the structural design criteria applied to the design of this project is as <br /> follows: <br /> Building Code FBC 17 6th ED Building Risk Category H <br /> Dead Load 2 psf Roof Live Load 20 psf -Reduction Allowed? Yes <br /> Collateral Load 5 psf Ground Snow Load,Pg 0 psf Nominal Wind Speed 108 m <br /> Snow Importance Factor,Is 1.00 Ultimate Wind Spee 140;n h Rain Intensity 11/12(in/hr) 10/13 <br /> Wind Exposure Category B <br /> Internal Pressure Coefficient,GCpi t 0.18 Wind Closure Category Enclosed <br /> Serviceability Wind Speed 78 mph Serviceability Wind Return Period 10 year <br /> Seismic Analysis Procedure Unit Lateral Force(Fx=0.01*W) <br /> Mapped Spectral Acceleration for Short Periods,Ss 0.068 Seismic Importance Factor,le 1.00 <br /> Mapped Spectral Acceleration for 1-Second Period,S1 0.034 Seismic Use Group N/A <br /> 5%Damped Spectral Acceleration for Short Periods,SDS 0.072 Seismic Design Category A <br /> 5%'Damped Spectral Acceleration for 1-Sec Period,SDI 0.054 Site Class D <br /> Design Base Shear,V CS•W Transverse Base Shear,V 0.8 kip Longitudinal Base Shear,V 0.9 kip <br /> Transverse Base Shear,V b=1.5 kip Longitudinal Base Shear,V b=2.3 kip <br /> Cs R <br /> Structural Systems,Transverse **N/A** 0.010 0 <br /> Structural Systems,Longitudinal(Front Sidewall) **N/A** 0.010 0 <br /> Structural Systems,Longitudinal(Back Sidewall) **N/A** 0.010 0 <br /> Structural Systems,Longitudinal(Left Endwall) **N/A*" 0.010 0 <br /> Structural Systems,Longitudinal(Right Endwall) **N/A** 0.010 0 <br /> Structural Systems,Longitudinal(Interior) <br /> This letter of certification applies solely to the above referenced project and its components as furnished by ACI Building Systems, <br /> LLC. Items specifically not covered by this letter of certification include, but are not limited to: any foundation design, masonry <br /> design,or general contract work. <br /> The design of the overhead door(s)is excluded from this certification.However,it is assumed in this design,with respect to building <br /> porosity,that the door(s)have been designed by the manufacturer to accomodate building wind loads and therefore the building is <br /> enclosed. <br /> This certification covers the static and dynamic forces acting on this project and its components as stipulated in the order <br /> documentation; however, ACI Building Systems, LLC. does not certify that the building code or loads specified in the order <br /> documentation are adequate or appropriate for the intended use or location of the project. <br /> Primary framing,secondary framing, screw-down sheeting, and stanffijm roof panels are manufactured at the ACI facility at <br /> 10125 Highway 6 West in Batesville,Mississippi. ��\�H P Sy�''-,, <br /> .��� ��'•�CAE/V <br /> Respectfully Submitted, •'••� �`'-• ��./�/' '"�`�� <br /> ACI Building Systems,LLC CA#8958 No 48014 • <br /> :7, :* <br /> .33 ' STATE OF '•�� <br /> Keith Shedd,P.E. �0 ' T <br /> �� <br /> Systems-Engineered Metal Building %��'• < O R <br /> Structural Engineer of Record �sss�••.....•• N � SLB <br /> NALE 0% <br /> P.O. BOX 1316, BATESVILLE, MS 38606, PI� EJ W563-4574, FAX 662-563-1142 <br />