Laserfiche WebLink
p <br /> i Q <br /> ,k <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401-3 of the F.B.C: <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required'before pouring concrete. . <br /> 5. Driveways require.a R.O:W use permit-. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All sethacks'shall be.met. <br /> 7. All,property markers shall be uncovered and marked at time of first inspection.' <br /> 8: All A.D.A.'requirements shall be,met: <br /> 9-. No electric,.plumbing;Mri chanical,-or framing shall be covered without an inspection and <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the F.B:C. (Fire Separation)•: <br /> 11. Appliances s,hall.not be installed in a location where subject to meclanical damage unless <br /> protected by approved barriers. M3034 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3.of the F:B.C: <br /> 13. Foundation supports for A/C units shall be raised at least'3" above finished grade. M 1308:1 <br /> 14. Return air in all bedrooms. F.B.-C. M162.0.4 <br /> 1.5. Smoke detectors are to be.installed in accordance with R313:1 of the_ .F.B.C. <br /> 16: All glazing requirenicht.s are to be in accordance with R308:4 of the F.B:C: <br /> 17. All means of egress are to be in accordance_with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702:4:2 F.B.C. <br /> 10. Co-mbination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate=from unit to unit: This includes all <br /> undergrbund:plumbing and electric. <br /> 22, All 2016 N.-E.C. Codes will be enforced: <br />