Laserfiche WebLink
IL <br /> 23. Tamper-'Resistant.Receptacles in accordance with 406.11 of"the 2016 N.E.0 <br /> 24."lh accordance with"the Land Development Code, lots".shall.be-sodded before final at least 10 <br /> feet"around the structure: <br /> 25: R403.5,3Hot water.pipe insulation <br /> lnsulation for hot.water pipe With-aminimum thermal-resistance (R-value) of-R-3 shall be applied to the <br /> following: <br /> Piping./: inch (19.1 mm) and larger_in nominal.diameter. <br /> Piping,serving more than:one dwelling unit. <br /> Piping located outside the cbrnditioned space:. <br /> Piping from thew at&heater to a distribution manifold:. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand'recirculationsystems. <br /> 25. Blower door test shall be provided;before C.O: ." <br /> 26.A cony of the energy cacls shall be:ivith permit at all dines <br /> 27.Copy of-final:insulation"reyort shall"be provided with Permit before�naL <br /> 28:No.fence."pool orsereen enclosure:is.issued.with:thispe.rmit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act_ N.E.C.-National Electric_Code (2016)" <br />