My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-135
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-135
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 9:07:22 AM
Creation date
3/2/2022 9:07:20 AM
Metadata
Fields
Template:
Building Department
Company Name
LENNAR HOMES LLC
Building Department - Doc Type
Permit
Permit #
20-135
Building Department - Name
LENNAR HOMES LLC
Address
3071 NUBBIN RIDGE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D <br /> Q` <br /> r <br /> • <br /> o <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E; shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6. All setbacks shall be-met. <br /> 7. All.property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be met: <br /> 9-. .No electric,plumbing;mechanical,or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302'.6 of the F.B.-C. (Fire Separation).: <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M3014 of the RB.0 <br /> 12. Water-heate' rs shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 . <br /> 14. Return air in all bedrooms. F.B.C. MI00.4 <br /> 15. Smoke detectors are to be.installed in accordance with_R313.1 of the F.B.C. <br /> 16:All glazing requirements are to be-in accordance with R308.4 of the F.B.-C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backeri in showers or tubs. 1t702:4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in-accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This include_ s all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.