Laserfiche WebLink
.23. Tamper- Resistant Receptacles in accordance with 406.11 of the.2016 N.E:C <br /> 24. In accordance with the Land Development Code,lots,shall be sodded before final at least 10 <br /> feet around the structure: , <br /> 25: R403:5.3Hot water.pipe-insulation <br /> Insulation forhot,water'pipe with a minimum thermal resistance (R-value) of.R-3.shall.be applied-to the <br /> following: <br /> Piping.31,inch (19.1.mm)and larger in:nominal diameter: <br /> • <br /> Piping.serving more than:one dwelling unit. <br /> Piping located outside the conditioned space:. <br /> Piping from the water heater to a distribution manifold: <br /> Piping'located under.a floor slab: <br /> Buried in piping.: <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.-Blower:door test shall be proviided,before C.O: - <br /> 26. A copy of the energy eacls'shall be with Oermit at all nines <br /> 27. Copy of final insulation retiort shall be provided with permit before fnab <br /> 28:No fence, pool onscreen enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.G.-Florida Biiilding Code Oh Edition <br /> R.O.W.-Right of Way.. <br /> A.D:A.--Americans with Disabilities Act N.E.C.-National Electric.Code(2016) - <br />