Laserfiche WebLink
Q <br /> I . <br /> 1 <br /> I <br /> �ff <br /> 1 <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F:F.E; shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2.. Lots shall be graded to comply with R401:3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill.dirt is brought in at any one.place. <br /> 4: tie'in' survey required before pouring'concrete. <br /> 5: Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A.'requirements shall be met: . <br /> 9: -No electric,plumbing.,mechanical, or framing shall be covered without an inspection and approval first. <br /> 10: All Garages shall comply with section R302'6 of the F.B:C. (Fire Separation): <br /> 11. Appliances shall.not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4.of the F.B.0 <br /> 12. Water heaters shall.comply with section P607.3 of the F.B.C., <br /> 13.Foundation supports for A/C units_shall be raised at least 3" above finished grade. M1308.:1 <br /> 14:.Returri air in all bedrooms: F.B:C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with.R313J of the F.B.C:. <br /> 16. All"glazingrequirements are to be in accordance with R308A of the F.B:C: <br /> 17. All means of egress are.to be in accordance with R31 I of the F.B.C. <br /> 18. "Green:gypsum,board" shall not be used as:a backer in showers or tubs:R702,:4:2 V.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground.plumbing and electric. <br /> 22: All 20T6 N.E.C. Codes will be enforced. <br />