My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-204
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-204
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 9:54:05 AM
Creation date
3/2/2022 9:53:57 AM
Metadata
Fields
Template:
Building Department
Company Name
SF ZEPHYR COMMONS LP
Building Department - Doc Type
Permit
Permit #
20-204
Building Department - Name
SF ZEPHYR COMMONS LP
Address
7910 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 t <br /> section <br /> # Final Inspection Complies? Comments/Assumptions <br /> & Req.ID <br /> C408.2.2 Construction documents require that a;❑Complies <br /> [FI54]3 written balance report be provided to ;❑Does Not <br /> the building owner or rep for HVAC <br /> systems serving zones with total ;❑Not Observable <br /> condition area > 5,000 sgft.Air ;❑Not Applicable <br /> distribution systems shall be tested, <br /> adjusted, and balanced by a licensed <br /> I engineer or certified company. <br /> C403.2.4. ;Automatic Controls:Setback to 551F f❑Complies <br /> 2.1, ;(heat)and 85°F(cool); 7-day clock, 2- ;❑Does Not <br /> C403.2.4, i hour occupant override, 10-hour <br /> 2.2 'backup I❑Not Observable; <br /> [F140]3 �❑Not Applicable <br /> C4043 Heat traps installed on supply and ;❑Complies I <br /> [FI11]3 discharge piping of non-circulating ;❑Does Not <br /> systems. <br /> ❑Not Observable <br /> ;❑Not Applicable <br /> C404.4 ;All piping insulated in accordance with '❑Complies <br /> [FI25]2 ;section details and Table C403.2,10. ;❑Does Not <br /> I❑Not Observable; <br /> ❑Not Applicable <br /> C404.6.1 Controls are installed that limit the ;❑Complies <br /> [FI12]3 operation of a recirculation pump ;❑Does Not <br /> i installed to maintain temperature of a ; <br /> storage tank.System return pipe is a :[-]Not Observable; <br /> dedicated return pipe or a cold water :,❑Not Applicable <br /> Fsupply pipe. <br /> C405.4.1 ;Interior installed lamp and fixture UComplies ;See the Interior Lighting fixture schedule for values. <br /> [F[18]1 lighting power is consistent with what ;❑Does Not <br /> is shown on the approved lighting <br /> plans, demonstrating proposed watts Z❑Not Observable <br /> are less than or equal to allowed ❑Not Applicable <br /> watts. <br /> C408.2.1 I Commissioning plan developed by ;❑Complies <br /> [FI28]1 :registered design professional or ;❑Does Not <br /> approved agency. <br /> 1❑Not Observable; <br /> ❑Not Applicable <br /> C408.2.3. ;HVAC equipment has been tested to ;❑Complies <br /> 1 ensure proper operation. ;❑Does Not <br /> [FI31]1 <br /> :[-]Not Observable' <br /> ❑Not Applicable <br /> C408.2.3. ;HVAC control systems have been ❑Complies <br /> 2 :tested to ensure proper operation, ❑Does Not <br /> [FI10]1 :.calibration and adjustment of controls. ❑Not Observable <br /> ❑Not Applicable <br /> C408.2.4 :Preliminary commissioning report ;❑Complies <br /> [FI29]1 ;completed and certified by registered ;❑Does Not <br /> design professional or approved <br /> agency. ;❑Not Observable <br /> ❑Not Applicable <br /> C408.2.5. ;Furnished HVAC as-built drawings ;❑Complies <br /> 1 j submitted within 90 days of system j❑Does Not <br /> [FI7]3 1 acceptance. ![--]Not Observable <br /> ❑Not Applicable <br /> 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) <br /> Project Title: Planet Fitness-Zephyrhills, FL Report date: 04/09/20 <br /> Data filename: C:\Users\msaarem\Dropbox\ProductionL2020.013 Planet Fitness-Zephyrhills, FL Mar\20.013 Page 16 of 18 <br /> Planet Fitness-Zephyrhills, FL-ComCheck.cck <br />
The URL can be used to link to this page
Your browser does not support the video tag.