Laserfiche WebLink
Section <br /> # Final Inspection Complies? Comments/Assumptions <br /> & Req.ID <br /> C403.2.4. Heating and cooling to each zone is UComplies <br /> 1 f controlled by a thermostat control. ❑Does Not <br /> [FI47]3 Minimum one humidity control device <br /> per installed ❑Not Observable <br /> humidification/dehumidification f❑Not Applicable <br /> I system. <br /> C403.2.4, j Heat pump controls prevent ❑Complies <br /> 1.1 jsupplemental electric resistance heat :❑Does Not <br /> [FI42]3 Ifrom coming on when not needed. <br /> ❑Not Observable <br /> j ;❑Not Applicable <br /> C403.2.4. ;Heat pump controls prevent ;❑Complies <br /> 1.1 supplemental electric resistance heat :❑Does Not <br /> [FI42]3 $from coming on when not needed. <br /> f( �❑Not Observable <br /> ❑Not Applicable <br /> C403.2.4. Heat pump controls prevent ;❑Complies <br /> 1.1 k supplemental electric resistance heat ;❑Does Not <br /> [.F142]3 from coming on when not needed. <br /> I ,❑Not Observable <br /> ❑Not Applicable <br /> C403.2.4. Thermostatic controls have a 5 °F I❑Complies <br /> 1.2 deadband. ;❑Does Not <br /> [F138]3 <br /> :[:]Not Observable <br /> t ;❑Not Applicable <br /> C403.2.4, Temperature controls have setpoint ;❑Complies <br /> 1.3 i overlap restrictions, ;❑Does Not <br /> [FI20]3 ;❑Not Observable <br /> y ;❑Not Applicable <br /> C403.2.4. Each zone equipped with setback ❑Complies ' <br /> 2 controls using automatic time clock or �❑Does Not <br /> [FI39]3 programmable control system. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C404.12.21 Public lavatory facilities equipped with E❑Complies <br /> [FI53]3 i outlet devices which limit the flow of ;❑Does Not <br /> hot water to a maximum of 0.5 gpm or, <br /> are equipped with self-closing valves �❑Not Observable; <br /> that limit delivery to a per cycle �❑Not Applicable <br /> maximum of 0.25 gallons of hot water <br /> ,for recirculating systems and to a I ' <br /> maximum of 0.50 gallons for non- <br /> recirculating systems. <br /> C404.12.2;Public lavatory water temperature ;❑Complies <br /> [Fi5713 #<=110°F, ;❑Does Not <br /> ❑Not Observable <br /> j ;❑Not Applicable <br /> C404.12.1 Showers used for non-safety reasons ;❑Complies <br /> [F152]3 ;equipped with flow control devices to '❑Does Not <br /> j limit the water discharge to a <br /> maximum of 2.5 gpm per shower ,❑Not Observable <br /> j head, Flow restricting inserts used as ;❑Not Applicable <br /> i a component part of a showerhead <br /> {are mechanically retained at the point <br /> {of manufacture <br /> 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) <br /> Project Title: Planet Fitness-Zephyrhills, FL Report date: 04/09/20 <br /> Data filename: C:\Users\msaarem\Dropbox\ProductionL2020.013 Planet Fitness-Zephyrhills, FL Mar\20.013 Page 15 of 18 <br /> Planet Fitness-Zephyrhills, FL-ComCheck.cck <br />