My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-211
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-211
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 9:57:57 AM
Creation date
3/2/2022 9:57:56 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-211
Building Department - Name
DR HORTON INC
Address
35592 STELLA VAST DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D <br /> Q <br /> i <br /> dt it <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. FYI, shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie iri survey required before pouring-concrete. <br /> 5, Driveways require a R.O:W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> T. All.property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9. No electric, plumbing-mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10.. All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation). <br /> 1,1. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall:comply with section P607.3 of the R.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.-C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308A of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. . <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 201-6 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.