Laserfiche WebLink
D <br /> Q <br /> I• <br /> Single Family Dwelling <br /> Plan Review Comments <br /> L. F.FE;.shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.comply with R401.3.of the F.B.C. <br /> 3.. C.ornpaction test required if 24"or more of fill dirt is brought in at any one.place. <br /> 4:' Tie in survey required before pouring concrete. <br /> .5. Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> .6. .All setbacks shall be met. <br /> ' <br /> 7. All:property markers shall be uncovered,and.marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be_met. <br /> 9: No electric,.plumbing;mechanical, or framing shall.be covered without an inspection.and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).: <br /> 11. Appliances shall not be installed in 'a location where subject to mechanical=damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C uriits.shall b:e raised at least 3" above finished grade. M1308:1 - <br /> 14: Return air in all bedrooms. F.B.C. M1620:4 <br /> 1-5. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall not be used as a backer in showers or tubs. R702.4.2 EB.C. <br /> 19: Combiriatiori-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that_uses fossil-burning heating <br /> or-appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />