OMEMO I etc. -
<br /> APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT R6 STANCE
<br /> TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
<br /> 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 -
<br /> 113 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-8
<br /> 1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9
<br /> 1D Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 10-11
<br /> 1E Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 12-14
<br /> 1F-1 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15-17
<br /> 1F-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 18-19
<br /> 1G Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 19
<br /> 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 20-22
<br /> 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 23-27
<br /> 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 28-30
<br /> 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-38
<br /> 3B Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 38
<br /> 3C Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 39
<br /> 4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 40-43
<br /> 4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 44-46
<br /> 4C Lightweight concrete New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47-52
<br /> 4D Lightweight concrete Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 52
<br /> 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 53
<br /> 5B Cementitious wood fiber New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 54
<br /> SC Cementitious wood fiber New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 55
<br /> SD Cementitious wood fiber New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 55
<br /> 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 56-58
<br /> 6B Existing gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Banded Insulation,Bonded Roof Cover 58-59
<br /> 6C Existing gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 59
<br /> 6D Existing gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 60
<br /> 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 61-67
<br /> 7B Various Recover F Non-Insulated,Bonded Roof Cover 67
<br /> NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-RZ3
<br /> Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 24:06/20/2019
<br /> Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlasticm Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 1 of 67
<br />
|