OONEMOjetc..- <br /> The following notes apply to the systems outlined herein: <br /> 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof <br /> deck shall be documented through proper codified and/or FBC Approval documentation. <br /> 2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: <br /> Wood Deck: OMG#14 Roofgrip with Flat Bottom Plate(Accutrac),OMG HD with OMG 3 in.Galvalume Steel Plate,Dekfast#14 with Hex Plate or 3"Round Insulation Plate,Trufast HD with Trufast 3" <br /> Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. <br /> > Steel Deck: OMG#12 or#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),CMG#12 Standard or HD with CMG 3 in.Galvalume Steel Plate,Dekfast#12 or#14 with Hex Plate or 3"Round <br /> Insulation Plate,Trufast DP or HD with Trufast 3"Metal Insulation Plates or FlintFast#12 or#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch steel penetration and <br /> engage the top flute of the steel deck. <br /> > Structural Concrete: OMG#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG HD or CD-10 with OMG 3 in.Galvalume Steel Plate,Dekfast#14 or DekSpike with Hex Plate or 3"Round Insulation <br /> Plate,Trufast HD or CF with Trufast 3"Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot <br /> hole in accordance with the fastener manufacturer's published installation instructions. <br /> 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,GlasRoc Roof Board or gypsum-based roof board that meets the CIA requirements <br /> of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. <br /> 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for,or installed beneath rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover), <br /> whereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck <br /> listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper <br /> codified and/or FBC Approval documentation. <br /> 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). <br /> 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. <br /> Y Hot asphalt(HA): Full coverage at 25-30 Ibs/square <br /> i Ashland Pliodeck(A-PD): Continuous 0.75 inch wide ribbons,12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. <br /> r Dow INSTA-STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1 inch wide ribbons,12-inch o.c. <br /> Y ICP Adhesives Polyset BOARD-MAX: Continuous 3-inch ribbons,12-inch o.c. <br /> Y ICP Adhesives Polyset CR-20: Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. <br /> Y Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. <br /> > Millennium PG-1 Pump Grade Adhesive(M-PGI): Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. <br /> OMG OlyBond 500 or OlyBond Green(OB500): Continuous 0.75-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot) <br /> Y Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,boards shall be staggered from layer-to-layer. <br /> Y Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. <br /> 7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum <br /> Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the <br /> thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: <br /> 7% Ashland Pliodeck(A-PD)@ 12-inch o.c. MDP -105.0 psf (Min.1.0-inch) <br /> Y Ashland Pliodeck(A-PD)@ 6-inch o.c. MDP -277.5 psf (Min.1.0-inch) <br /> > Dow INSTA-STIK Quik Set Insulation Adhesive(D-IS): MDP -120.0 psf (Min.1.0-inch) <br /> > ICP Adhesives Polyset CR-20: MDP -117.5 psf (Min.1.0-inch) <br /> Y Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.1.0-inch) <br /> Y Millennium PG-1 Pump Grade Adhesive(M-PG1): MDP -157.5 psf (Min.1.0-inch) <br /> y OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch Multi-Max FA3) <br /> Y OMG OlyBond 500(0B500): MDP -187.5 psf (Min.0.5-inch ISO 95+GL) <br /> Y OMG OlyBond 500(O13500): MDP -315.0 psf (Min.0.5-inch ENRGY 3) <br /> Y OMG OlyBond 500(0B500): MDP -487.5 psf (Min.0.5-inch ACFoam II) <br /> NEMO ETC,LLC Evaluation Report 3520.03.04-1124 for FL2533-R23 <br /> Certificate of Authorization#32455 61"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 24:06/20/2019 <br /> Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 2 of 67 <br />