Laserfiche WebLink
FORM 13405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department,of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Abraham-5843 17th St Builder Name: <br /> Street: 5843 17th St Permit Office:•:Zephyrhills <br /> City,State,Zip: Zephyrhills, FL,33542.. Permit-Number:141 <br /> Owner: Jurisdiction: 611600 <br /> Design Location: FL, Lakeland County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing Addition 9. Wall Types(760:0 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a. Face Brick-Block, Exterior R=4.1 760.00 ftz <br /> b. N/A R= ftz <br /> 3. Number of units,if multiple family 1 c. N/A R= ftz <br /> 4. Number of Bedrooms(Bedrms In Addition) 1(1) d. N/A R=. ftz <br /> 10.Ceiling Types (598.0 sgft.) Insulation Area <br /> 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 598.00 ftz <br /> 6. Conditioned floor area above grade(ftz)' 598 -b. N/A'. R= ftz <br /> Conditioned floor area below grade(ftz) 0 c. N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(30.0 sgft.) Description Area <br /> a. U-Factor: Dbl, U=0.57 30.00 ftz <br /> SHGC: SHGC=0.24 <br /> b. U-Factor: N/A {tz 12.Cooling systems 'kBtu/hr Efficiency <br /> SHGC: a.Central Unit - 9.0..SEER:18.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13. Heating systems kBiu/hr Efficiency <br /> d. U-Factor: N/A ftz a. Electric Heat Pump 9.0 HSPF_:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.000 ft. <br /> Area Weighted Average SHGC: 0.240 14. Hot water systems-Replacement equipment <br /> 8. Floor Types (598.0 sgfi.) Insulation Area a. Electric ' Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 598.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c. N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.050 Total Proposed Modified Loads: 15.06 PASS <br /> Total Baseline Loads: 20.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O��[IiE S��?� <br /> this calculation are in compliance with the Florida Energy specifications covered bythis <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY("! � � E-Calcs Plus, Inc. Before construction is completed <br /> DATE: July 15:202o this buildin will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. G'OD WE's¢`� <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).(Exception may apply) <br /> 7/15/2020 8:25 AM EnergyGauge®USA 6.0.&(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />