My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-347
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-347
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 3:59:00 PM
Creation date
3/3/2022 3:58:58 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-347
Building Department - Name
DELAMORA,ABRAHAM
Address
5843 17TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> PROJECT <br /> Title: Abraham-584317th St Bedrooms: 1 Address Type: Street Address <br /> Building Type: User Conditioned Area: 598 Lot# <br /> Owner Name: Total Stories: 1 Block/Subdivision: <br /> #of Units: 1 Worst Case: No PlatBook: <br /> Builder Name: Rotate Angle: 0 Street: 5843 17th St <br /> Permit Office: Zephyrhills Cross Ventilation: No County: Pasco <br /> Jurisdiction: 611600 Whole House Fan: No City,State,Zip: Zephyrhills, <br /> Family Type: Single-family FL, 33542 <br /> New/Existing: Addition <br /> Comment: <br /> CLIMATE <br /> / Design Temp I,nt Design Temp Heating Design Daily Temp <br /> Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range <br /> FL, Lakeland FL_LAKELAND_LINDER 34 92 70 75 973 48 Medium <br /> BLOCKS <br /> Number Name Area Volume <br /> 1 Entire House 598 5980 <br /> SPACES <br /> Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated <br /> 1 Addition BA 99 990 No 0 1 Yes Yes Yes <br /> 2 Addition Utility 108 1080 No 0 1 Yes Yes Yes <br /> 3 Adition BR 391 3910 No 2 1 1 Yes Yes Yes <br /> FLOORS <br /> # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet <br /> 1 Slab-On-Grade Edge Insulatio Addition BA 11 ft 0 99 ft2 ____ 1 0 0 <br /> 2Slab-On-Grade Edge Insulatio Addition Utility 21 ft 0 108ft2 ____ 1 0 0 <br /> 3 Slab-On-Grade-Edge Insulatio Adition BR 44 ft 0 391 ft2 ---- 1 0 0 <br /> ROOF <br /> Roof ,_ Gable Roof Rad Solar SA Emitt Emitt Deck Pitch <br /> Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) <br /> 1 Gable or Shed Composition shingles 616 ft2 74 ftz Medium N 0.8.5. - No 0.9 No 0 14 <br /> ATTIC <br /> V # . Type Ventilation Vent Ratio(1 in) Area RBS IRCC <br /> 1 Full attic Vented 150 598 ft2 N N <br /> 7/15/2020 8:25 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.