Laserfiche WebLink
Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401:3 of the F.B.C. <br /> 3. . Compaction test required if 24"or more of fill dirt is brought in at any one.place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. 'Driveways require a R.O:W. use permit: All 4 sides of driveway_ thru the sidewalk shall have <br /> expansibii material.. <br /> 6'. All setbackg shall be met. <br /> 7. All property markers shall be uncovered and marked at time:of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and <br /> approval first: <br /> 10: All.Garages shall comply with section R302:6 of the F.B:C. (Fire Separation).: <br /> 11. Appliances shall not be installed in a location where subject.to mechanical damage unless <br /> protected by approved barriers. M303;4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of-the FAIC: <br /> 13: Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors.are to be installed in accordance with,R313.1 of the.F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17..All means.of egress are to-be in accordance with R311 of the F.B.C. <br /> 18. ``Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> -20. Carbon nionokide.alarms will be required in new construction that uses fossil-burning heating <br /> or_appliances or an attached garage. They shall be installed-in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />