Laserfiche WebLink
.23:Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E;C <br /> 24. In accordance with the Land Development Code,lots shall be-sodded_ -before final at least.10 <br /> feet around the structure: . <br /> 25-. R403.5.3Hot water pipe.insulation <br /> Insulation for.hot;water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the' <br /> following: <br /> Piping:/; inch (19:1 mm)and larger in.nominal diameter: <br /> Piping serving more than one dwelling unit: <br /> Piping located outside the conditioned space.. <br /> Piping from the water heater to:a'distribution manifold: <br /> .Piping:located under a floor slab. <br /> Buried in' -piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems: <br /> 25: ]Blower door test shall be provided Before C.O; <br /> .26.A copy ofthe enerQy rack shall be with permit at all times <br /> 27.Copy of final insulation report shall be Provided with Permit before rnaL <br /> 28. No fence, pool or -enclosure :is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F:B.0 Florida Building Code 6d Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />