Laserfiche WebLink
D <br /> Q <br /> k <br /> Single -Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E...shall:be a minimum of 8" above the road elevation and an engineered-site plan. <br /> 2: Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5: Driveways require.a R,O:W. use permit_. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6! All setbacks shall be met. <br /> 7: All property markers shall be uncovered.and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> V. No.electric,plumbing,mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages,shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected. approved barriers. M303;4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 ofthe. T.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308.:l . <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the-F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308A of the F.B.C: <br /> .. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide.alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall he separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2u6 N.E.C. Codes will be enforced: <br />