My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-410
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-410
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 6:33:41 AM
Creation date
3/4/2022 6:33:40 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-410
Building Department - Name
DR HORTON INC
Address
35574 BURMA REED DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D <br /> Q' <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F RE, shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. .Lots shall be graded to comply with R401.3 of the F.B.C: <br /> 3:. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6. .All setbacks shall be met. <br /> T. All property markers shall be uncovered.and.marked at time.of first inspection. <br /> . <br /> 8: All A:D.A."requirements shall be met: <br /> 9. No electric,plumbing;mechanical, or.framing shall.be:covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11.Appliances shall not b.e installed_ in a location where subject.to mechanical damage unless <br /> protected by approved barriers. M303A of the F.B.0 <br /> 12. water heaters shall comply with section P607.3 of the F.B:C: <br /> 13. Foundation supports for A/C units.shall.be raised at least 3" above finished grade. M1308:1 <br /> 14: Return air In all bedrooms. F.B.C. M1620A <br /> 1-5. Smoke detectors are to be installed in accordance with.R3.13.1.of the F.B.C. <br /> 16. All glazing requirements are to be J accordance with R308:4 of the F:B:C: <br /> 17. All means of egress are to be in accordance=with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not.be used as a backer in showers or tubs. R702.4.2 P.B.C. . <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating. <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall l he separate from unit to unit. This includes all <br /> underground plumbing and.electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.