Laserfiche WebLink
23. Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation <br /> Insulation for hot water. pipe with'a minimum thermal resistance (R-value) of R-3.shall be applied to the . <br /> following: _ <br /> Piping V: inch (19.1 mm)and larger in.nomina[diameter. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space:. <br /> Piping from the watetbeater to a distribution manifold: <br /> Piping-located under-a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C.O. <br /> 26. A copy of the enemy-cacls shall be with permit at all dines. <br /> 27. Copt/of final insulation report shall be provided with peen:it before fnaL <br /> 28. No fence, pool or'screen enclosure .is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6 b Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) -. <br />