Laserfiche WebLink
i <br /> i <br /> D <br /> Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> I Lots shall be graded to comply with R401:3 of the F.B.C.. <br /> 3. Compaction test required.if 24"or more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> .5-. Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. An property markers shall be uncovered.and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met: <br /> 9. No electric,.plumbing,mechanical, or framing shall be:covered without an inspection.and <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the FAIC. (Fire Separation)... . <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by.approved barriers. M303;4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13: Foundation supports for A/C units shall b:e raised at least 3" above finished grade. M1308..1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of theB F. .C. <br /> 16.-All glazing requirements are to be in accordance with R308A of the F.B:C: <br /> 17. All means of egress are to be in accordance with R311 of the RB.C. <br /> 18. "Green gypsum board" shall not be used as-a backerin showers or tubs. R702A.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monokide alarms will:be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> -2.1. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />