Laserfiche WebLink
w <br /> 4 <br /> Single .Family Dwelling <br /> Plan Review Comments <br /> 1. F.EE. shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.con ply with R401.3 'of the F:B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place, <br /> 4: Tie in survey required before,pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk.shall have <br /> expansion material.. <br /> 6. All setbacks shall be met. <br /> -7: All property markers shall be uncovered and marked at time.of first inspection. <br /> 8: All A;D.A.'requirements shall be.met: - <br /> 9. No electric,plumbing, mechanical,--ow frarning shall be covered without an inspection and <br /> Approval first: <br /> 10. All Garages shall comply with section R302.6 of the F.B:C. (Fire Separation}. <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4,of the FB:C <br /> 12. Water heaters shall comply with section 1?607.3 of the F&C. <br /> 13. Foundation supports for AlC units shall be raised at least 3"above finished grade. M1308.:1 <br /> 14. Return air in all bedrooms: F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in-accordance with R313:1 of the RB.C. <br /> 16.All glazing requirements are to b.e in accordance with R308.4 of the F.B:C: <br /> I- All means of egress are to be in accordance with R311 of the F.B.C: <br /> 18. "Green gypsum board"shall not be used as a backer in showers or tubs.R702.4,2 EB.C. . <br /> 19. Combination-type AM breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide Alarm" swill be required in new construction that uses fossil-buring heating <br /> or appliances or an attached garage.- They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground,plumbing and electric. <br /> M All 2016 NIX.'Codes will be enforced. <br />