Laserfiche WebLink
1 <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordancewith the Land Development Code, lots shall be sodded before final at-least 10 <br /> feet'around the structure. <br /> 25. R403.'5.3Hot Water.pipe insulation <br /> Insulation for hot Water pipe with a minimum thermal resistance (R-value) of.R-3 shall be applied to the <br /> following': <br /> Piping V. inch (19.1.'mm) and larger.in nominal diameter.. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the.water heater to a distribution manifold: <br /> Piping located under a floor slab. <br /> Buried in piping,. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower:door test shall be provided.before C.O: <br /> 26.A cony of the energy.cacls shall be with-permit at all times <br /> 27. Copy of final insulation report shall be provided ivith Permit before rinal <br /> 28. No- ence,pool or screen enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.0 Florida Building Code 6th Edition <br /> R.O.W..-Right of Way. <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code(2016) <br />