Laserfiche WebLink
Single :Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E: shall be a minimum of 8" above the road elevation and an engineered site plan_ . <br /> 2. Lots shall be graded to.cornply with R401.3:'of the F.B.C. <br /> 3: Compaction test required if 241'or more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before.pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered.and marked_ at time of first inspection. <br /> 8: All A.D.A.-requirements shall be.met: <br /> 9: No electric,.plumbing;mechanical,or.framing shall be covered without an inspection and <br /> approval-f rst. <br /> 10. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 1,1. Appliances shall not be installed-iii a location where subject to mechanical damage unless <br /> protected by approved barriers. M3034 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the FBI .C. <br /> 13. Foundation supports for A/C uhits:.shall be raised at least 3"-above fin_ ished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313:1.of the F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All.means of egress are to . in accordance:with R311 of the F.B.C. . <br /> 18. "Green gypsum.board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination type AFCI breakers are required at all locations requiring:an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that-uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />