Laserfiche WebLink
The Association of <br /> v�L1P Poo/&Spa Professionals® <br /> ANSVAPSPACC 15a ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS <br /> PROJECT NAME: Lyudmila & Nelson Arce CONTRACTOR NAME Patio Pools Inc <br /> AND ADDRESS AND ADDRESS: <br /> 6526 Wagon Trail St 4118 Gunn Highway <br /> Zephyrhills, FI 33541 Tampa, FL 33618 <br /> OWNER:same as above CONTRACTOR PHONE:(813) 962-0374 DATE:6/30/2020 <br /> This information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa <br /> Professionals(APSP). It is not part of the American National Standard ANSI/APSP/ICC-15a 2011 but is included for information only.Contractors should acquire and comply <br /> with the ANSI/APSP/ICC-1Sa 2011 standard which can be purchased at www.apsp.org. <br /> 1. §5.2.1:Calculated pool volume <br /> a. Gallons: 10,000 ;or 1, : 10,000 gallons _ <br /> b.Calculated Gallons: (surface area)X (average depth)X 7.48 (gal/ft^3) = D <br /> 2.§5.2.1:Calculated filtration flow rate 2. 36 gpm <br /> (Pool volume-360 or 36gpm whichever is larger) <br /> 3.§5.5.1:Pipe sizing: <br /> a.Minimum suction pipe diameter 3a. 1.5 inches _ <br /> (Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than item 2.) <br /> b.Minimum suction branch pipe diameter 3b. 1.5 inches _ <br /> (Calculate:Item 2. 36 (gpm)_Branch Pipes 1 (quantity)=branch flow rate 36 (gpm). <br /> Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than the calculated <br /> suction branch flow rate.) <br /> c.Minimum return pipe diameter 3c. 1.5 inches _ <br /> (Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than item 2.) <br /> d.Minimum return branch pipe diameter 3d. 1.5 inches _ <br /> (Calculate:Item 2. 36 (gpm)_Branch Pipes 1 (quantity)=branch flow'rate 36 (gpm). <br /> Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the some or more than the calculated <br /> return branch flow rate.) <br /> 4.§5.4.1:Filter type and size: <br /> a.Filter type:(Cartridge,DE,Sand) 4a.Cartridge <br /> b.Minimum filter area 4b. 96.0 s ft. <br /> (Calculate:item 2. 36 (gpm)_filterfactor 0.375 (gpm/ft^2)) q <br /> Filter factors:Cartridge=0.375, Sand=15,Diatomaceous Earth=2 <br /> S. §5.4.2:Backwash valve: 177 Yes, ONO 2 <br /> S. inches - <br /> (when using a backwash valve,enter result of item 3c or 2 inches whichever is larger) <br /> Table 1 (When used) <br /> - Pipe Size:' 1.5" 2" '2:5" 3" !3.5" 5" 6" <br /> Nominal GPM @ 6 fps 38 63 90 138 1 185 1.238 374 1 540 <br /> Nominal GPM @ 8 fps 51 84 119 184 1 247 317 499 1 720 <br /> 6.Single-speed pump selection(when used): <br /> §5.1.1,5.3.1:For single-speed pumps with a total horsepower 0.99 or less,find and enter,a compliant pump from the Pool Pump <br /> Database. <br /> a.Pump model 6a. <br /> b.Total horsepower 6b. <br /> 7.Multi-speed pump selection(when used): <br /> §5.3.2.1:Pools 17,000 gallons or less,select pump*from the database with a Curve-A gpm flow equal to item 2 or less. <br /> §5.3.2.2:Pools 17,001 gallons or more,select pump*from the database with a Curve-C gpm flow equal to item 2 or less. Or <br /> *Multi-speed pumps must have one speed listed that satisfies this requirement. <br /> a.Pump model 7a.Intelliflo VS <br /> b.Pump flow 7b. 18 gpm _ <br /> (§5.3.2.1,5.3.2.2:Applicable Curve A or C gpm flow listed in database) <br /> 3/17/15 ANSI/APSP/ICC-15 Standard Writing Committee Form 1 of 2 <br />