Laserfiche WebLink
ANSI/APSP/ICC 15 ENERGY.EFFICIENCY.COMPLIAN.CE INFORMATION FOR RESIDENTIAL SWIMMING POOLS <br /> Component Section Requirements Check <br /> 4.4.1.1 Heater,has no pilot light <br /> 4.4.1.2 Readily accessible on-off switch mounted outside of the heaterFv <br /> Heaters No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation, <br /> 4.3.1.3 <br /> or for pool with 60%of documented pool heating from on-site solar or recovered energy. <br /> 4:3.2 Heater efficiency:gas/oil fired heater efficiency at least 78%,heat pump COP at least 4.0 <br /> 5.1.1 Pool filter pump listed in database <br /> 5.3.1 Pool filter pump with total horsepower 1.0.or more is multi-speed_ <br /> Multi-speed pump controller programmed to default to the filtration flow rate when no auxiliary <br /> 5.3.3 pool loads are operating within 24 hours and programmed with temporary override capability for, <br /> servicing. <br /> Pool systems 5.3.4 Single-speed pump controller capable of operating pump during off-peak electric demand. <br /> 5.5.2. Pipe before pump has at least 4 diameters of straight pipe. <br /> System installed with solar,or setup for the future addition of solar heating equipment by <br /> 5.5.3 installing 18 inches of horizontal or vertical pipe after the filter and before a heater,or built-in orFv <br /> built-up connections,or dedicated pipe to and from the pool. <br /> 5.6 [Directional inlets for mixing pool water. <br /> -,3/17/15 ANSI/APSP/IC&15 Standard Writing Committee Form 2 of 2 <br />