Laserfiche WebLink
y <br /> ti <br /> D <br /> Q f <br /> .Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E;,shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.comply with R401:3 'of the F.B.C:. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before,pouring concrete. <br /> . . <br /> .5: Driveways require a R,O:W. use permit. All 4 sides of driveway thru the sidewalk shall have- <br /> expansion material. <br /> 6: .All setbacks shall be met. <br /> 7: All,property markers shall be uncovered,and marked at time:of first inspection. <br /> 8: All A.D.A.requirements shall be met: <br /> .9: -No electric,.plumbing;mechanical,or.framing shall be:covered without an inspection.and . <br /> -approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location.where subject:to mechanical-damage unless <br /> protected by approved barriers. M303:4 of the F:B:C <br /> .12. Water heaters shall comply with section P607.3 ofthe F:B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1: . <br /> 14-Return air in all bedrooms: F.B:C. M1620.4 <br /> . <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16:All glazing requirements are to bean accordance'with R308A of the F.B.C. <br /> 17. All means.of egress are.to be in accordance with R311 of the F.B.C. <br /> 18. "Green.gypsum,board"-shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19:.Combiriation-type AFCI-breakers are required at all locations requiring an AFCI type breaker. <br /> '20. Carbon monoxide alarms will be required in new construction that.uses fossil-Burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the'F B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 21 All 2016 N.E.C. Codes will be enforced: <br />