Laserfiche WebLink
23. Tamper- Resistant Receptacles i.n accordance with 406.11 of the,2016 N.E:C <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water-pipe.insulation <br /> insulation forhot water'pipe with a minimum thermal resistance(R-value) of R-3 shall be applied to the <br /> following: <br /> Piping•/: inch (19:1 mm)and larger .in.nominal diameter: <br /> Piping serving more than one dwelling unit. <br /> Piping located outside'the conditioned space: <br /> Piping-from the.waterheater to:a:distribution manifold:_ <br /> Piping.located under a floor slab: <br /> Buried in piping,' <br /> 'Supply and return piping in recirculation systems other than demand recirculation systems, <br /> 25.Blower door test shall be provided before C.O. <br /> 26 A copy of the enerQy each shall be with permit at all times <br /> 27. Copy of final insulation report shall be provided ivith permit before finaA- <br /> 28.Nofe nce,pool or screen enclosure :is issued with ahis-permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C=.:Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act . N.E.C.-National Electric.Code(2016) <br />