Laserfiche WebLink
�O <br /> t <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1.: F.F.E; shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to cornply with R401.3.'of the F.B.C: <br /> 3. Compaction test required if 24" or more offill-dirt is brought in at any one.place. <br /> . <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways require a R.O.W. use permit. All 4 sides of driveway thra the sidewalk shall have <br /> expansion material. . <br /> 6: All setbacks shall be met. <br /> T. All property markers shall be uncovered-and marked at time of first inspection. <br /> 8: .All A.D.A.re' quiremerts shall be met: . . <br /> 9: No electric,plumbing;mechanical, or framing shall_be covered without an inspection.and <br /> approval first: <br /> 10. All Garages shall comply with section R3026 of the F.B:C. (Fire Separation).:- <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B:C. <br /> 13. Foundation supports for A/C tiriits:shall be raised at least 3"-above finished glade. M1308.1 . <br /> 14. Return air in.all bedrooms. F.B:C. M1620.4 <br /> 1.5. Smoke detectors.are to be installed in accordance with,R3.13:1 of the.F.B.C. <br /> 16.A11 glazing requirements are to be-in accordance with R308.4 of the F.B.-C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs:R702.4.2 F.B.C. . <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall'be separate from unit to unit. This includes all <br /> underground.plumbing and electric. <br /> 22. A112016 ME.C. Codes will be enforced: <br />