Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.41 of the 2016 N.E.0 <br /> .24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25.. R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe with'a minimum thermal resistance(R-.value) of R-3 shall. be applied to the <br /> following: <br /> Pipin 3/;inch (19A mm and larger_in nominal diameter.. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution manifold,, <br /> Piping located under a floor slab. <br /> Buried in piping,: <br /> Supply and return piping in recirculation'systems other than demand recirculation systems: <br /> 25.-Blower door test shall be provided before C.O: <br /> 26.A cony ofthe energy:cacls'shall be with permit at all times- <br /> 27. Copy of final insulationreport shall be provided ivith permit before final <br /> 28:No fence,pool or screen enclosure Is issued with:this permik <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code(2016) <br />