My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1413
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1413
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 2:03:38 PM
Creation date
5/9/2022 7:20:07 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1413
Building Department - Name
MUNOZ,ROSAIDY & SERRANO
Address
7808 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROCK- IT S Y STe M 4.0 <br /> sYSTem sPecIFIcaTions <br /> Max No.of Panels 300 Modules per ground lug Materials 300 Series Stainless, <br /> 6000 Series Aluminum <br /> Max System Voltage 1000VDC Coating BlackAndodization/Mill Finish <br /> Class A Fire.Rating With UL1703 Type 1 Rated Lug Specifications. Burndy CL50-1TN.Ground Lug <br /> Modules;see note below. .(UL Listing#KDER E9999) <br /> Leveling Range 3-4" Ground Wire 14 AWG-4 AWG Copper <br /> Per above Lug spec. Ground Wire <br /> Rock-It Slide Comp Range 3" Max Module Size 64.96"(1650mm)x <br /> Rock-It Slide Tile T' 39.05"(992mm)x 2"(50mm) <br /> Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45-PSF <br /> Max Anchor Spacing(35mm/40mm) .72" Rock-It Mount Load Rating 547lbs with Single 5/16"Lag 3.0 <br /> Max Anchor Spacing(32mm) 48" Safety Factor <br /> Skirt Box QTY 6 units Slide Fastening Hole 5/16"diameter <br /> Mount Box QTY 1.2 units Module Cantilever Maximum cantilever is 1/3 <br /> Rock-It Slide Box QTY 50 units bracket spacing <br /> Coupling Box QTY 12 units Warranty 1.20Year Material and Workman- <br /> ship <br /> Codes:National Electric Code,ANSI/NFPA.70,NEC 250;NEC 690,IRC;IBC <br /> Standards:UL 2703:First Edition,UL 1703 <br /> ,pt, �,'BF.coF.+,t.S.tur <br /> L[oliutcn$O�aY ROCK IT SYSTEM <br /> ROpKK�,naSTEM MFG IO CODE OGT.Q2-7016 <br /> CONFORMSTO UL7F07 CONFORMS TOUL2703 <br /> lOM G1P'4 YCix5TAWTKM <br /> ,savv�-n WNWLiOxI"MWlP1G5 <br /> ....-.._.-.O /Ssoal>•�vmm scicau uoDut£5 <br /> The EcoFasten Solar Rock-It System is a rooftop PV racking system consisting of 6000 Series Aluminum and 300 Series <br /> Stainless Steel components.The Rock-It System includes the rack components but does not include the PV. panels, <br /> inverters or electrical components.The PV modules to be used with Rock-It shall be certified under UL.1703.The <br /> system shall be used on steep slope roofs mounted over a Class A-fire rated roofing material and attached to the roof <br /> structure using 5/16"diameter,minimum 4"long 300 series Stainless Steel:lag bolts with minimum thread <br /> embedment depth of 21/2"into the roof structure. <br /> Periodic re-inspection for loose components <br /> The system is subject tore-inspection.as required by the PV module manufacturer or by the Authority Having <br /> Jurisdiction._Re-inspection,as required,should include evaluation of any loose components or loose fasteners.All <br /> loose components and fasteners should be secured in accordance with these instructions.The system should also be <br /> evaluated for any evidence of.corrosion.Any corrosion should be removed.Any affected part should be cleaned.or <br /> replaced in accordance with these instructions. <br /> P®a <br /> 'a v EeoFasten Solar' <br /> www.ecofastensolar.com info@ecofastensolar.com :877=859-3947 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.