D <br /> Q <br /> 0 <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E; shall be a mim*mum of 8" above the road elevation and an engineered site plan. <br /> 2 Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required.if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey ,required before pouring concrete. <br /> 5-. Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection_ . <br /> 8: All A.D:.A.'requirements shall be met. <br /> .9. No electric,plumbing;mechanical, or framing shall be covered without an inspection and <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject.to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1309A <br /> 146 Return air in all bedrooms. F.B.C. M162.0.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirenients are to be in accordance with R308A of the F.B.C. <br /> 17. All means of egress are to:be-in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are'required at all locations requiring an AFC type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the'F B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground.plumbing and electric. <br /> 22. All 20M N.E.C. Codes will be enforced. <br />