Laserfiche WebLink
} <br /> FORM R405-2020 <br /> FLORIDA ENERGY EFFICIENCY�CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941AB sf ADS 1936 4 bed 40GEWH Builder Name: LennarHomes 0237 <br /> Street: 39752 Harvest Creek Lane Permit Office: V%Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner: Lennar Homes Jurisdiction: 61 600 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 10. Wall Type$1668.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 72.70 ft' <br /> b.Frame-Wood,Adjacent R=11.0 86.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A <br /> R= ft2 <br /> 4. Numberof Bedrooms 4 d.N/A R= ft2 <br /> 11.Ceiling Types (2040.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 <br /> 6. Conditioned floor area abovegrade(ft2) 1936 b.Knee Wall(Vented) R=30.0 104.00ft2 <br /> Conditioned floor area belowgrade(ft2) 0 c.N/A R= ft2 <br /> 7. Windows(157.3 sqft.) Description Area 12•Ducts R ft2 <br /> a.Sup:Attic,Ret:Main,AH:Main 6 309.7 <br /> a. U-Factor: Dbl,U=0.33 101.00 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.55 33.33 ft2 13.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.33 23.00 ft2 <br /> SHGC: SHGC=0.21 14.Heating systems kBtu/hr Efficiency <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> a.Electric Heat Pump 34.6 HSPF:8.50 <br /> Area Weighted Average SHGC: 0.250 <br /> 8. Skylights Area <br /> c. U-Factor:(AVG) N/A ft2 15.Hotwatersystems <br /> SHGC(AVG): N/A a.Electric Cap:40 gallons <br /> 9. FloorTypes (1936.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservationfeatures <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 16.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 57.28 PASS <br /> Total Baseline Loads: 58.44 <br /> hereby certify that the plans and specifications covered by Review of the plans and ��. IrIE_Sr�? <br /> this calculation are in compliance with the Florida Energy specifications covered by this p <br /> Code. calculation indicates compliance �'��i� A� <br /> with the Florida Energy Code. ti 1nr '' ? ,ti•O <br /> PREPARED BY: DG-� .A� Before construction is completed <br /> DATE: this building will be inspected for - a. <br /> compliance with Section 553.908 <br /> hereby certify that this building, as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. n O CQD yyE � ' <br /> OWNER/AGENT: �• V BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires <br /> an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 <br /> .2.3 <br /> 1/12/2021 1:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 <br />