Laserfiche WebLink
ED <br /> Single Family Dwelling <br /> Plan Review Comments" <br /> L. F.F.E.. shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2.. Lots shall be graded to comply with R401.3:of the F.-B.C. <br /> 3: Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk'shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 1. All property markers sliall be uncovered.and marked at time of first inspection. <br /> 8: All A.-D.A.requirements shall,be.met: <br /> 9: No electric,.plumbing;mechanical, or.framing shall,.be covered without an inspection.and <br /> approval first. <br /> 10, All_Garages shall comply with section R302.6 of the F.B.C. (Fire Separation):. <br /> 11. Appliances shall-not be installed in a location where subject to mechanical damage unless <br /> an <br /> protected by.approved barriers. M303.A of the F.B.-C " <br /> 12. Water heaters shall comply with section P607.3 of the.F:B.C: <br /> 13. Foundation supports for A/.0 units shall be raised at least 3"-above"finished grade. MI-308A <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313-.1 of the F.B.C. <br /> 16.All glazing requirements are to be iri accordanee:'with R308.4-of the F:B:C: <br /> 17. All means.of egress are to-be in accordance with R311 of the F.B.C.. <br /> 18. "Green gypsum board" shall not be used as a backer"in showers or tubs. R702:4:2 F:B:C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22: All 201'6 N.E.C. Codes will be enforced. <br />