Laserfiche WebLink
D <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a inininium of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3.of the F.B.C: <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before,pouring_concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be-met. <br /> 7: All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A:D.A.'requirements shall be met: . <br /> 9-. No electric,plumbing;mechanical, or framing shall.be covered without an inspection and <br /> - approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.&C. <br /> 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308:1 . <br /> 14. Returri air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R3.13.1 of the F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are.to be in accordance with-R311 of the RB.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B:C. <br /> I9: Combination-type AM breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will.be required in new construction that uses fossil-Burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate-from unit to unit. This includes all <br /> underground:plumbing and electric. <br /> 21 All 2016 KE.C. Codes will be enforced: <br />