Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 244. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water.pipe insulation. <br /> Insulation for hot.water'pipe with'a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: . <br /> Piping 31, inch-(19.1 mm)and larger in nominal diame_ter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located.outside the conditioned space, <br /> Piping from the water heater to a distribution manifold. <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower:door-test shall be provided before C.O. <br /> 26.A copy of the energy-cacls shall he with permit at all times. <br /> 27. Copy offinal.insulation reoort shall be provided with permit before final <br /> 28. No fence,pool or screen'enclosure':is issued with thikoern:iz <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t' Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br /> 1 <br />