Laserfiche WebLink
4 <br /> Single- Family Dwelling <br /> Plan Review Comments <br /> L. F:RE; Shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> I Lots shall be graded to comply with R401:3 of the F.B.C: <br /> 3. Compaction test required if 24".or more of fill.dirt is brought in at any one.place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5-. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> `7. All property markers shall be uncovered.and marked at time of first inspection. <br /> 8:. All A.D.A. requirements shall be met: <br /> 9. No electric,.plumbing,mechanical, or framing shall be covered without an inspection.and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where'subject.to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall.comply with section P607.3 of the ERE. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.:1 . <br /> 14. Return air,in all bedrooms. F.B.C.. M1620A <br /> 1.5. Smoke detectors are to be-installed in accordance with R313.1 of the_F.B.C:. <br /> 16:All glazing requirements are to be in accordance with R308A of the F.B.C: <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C.. <br /> 18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4.2 F.B.C. . <br /> 10. Combination-type AM breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed-in accordance with the F.B.0 <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />