Laserfiche WebLink
Snow Load 0-20:psf <br /> Modules in Landscape <br /> Wind-Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch-<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 : Zone 3 Zone 1. : Zone 2 Zone 3 <br /> B 159 '93 59 <br /> 85 mph ,11'0 mph C 114 67 42 88 88 <br /> D 96 56 _35 91 74 74 <br /> 90 mph 115 mph C 104 61 38 98: 80 80 <br /> D 88 51 32 83 68- -68 <br /> B a 123 72 45 95 95 <br /> 100 mph .125 mph ' C 88 51 32 83 68 68 <br /> — D_ 74 43 _ 2_7_ 70—.-- '57 57 <br /> - i --�B 98 57 36 93! � 76— 76 <br /> 110.mph . . 140 mph- C 70. 41 26 66 54 54 <br /> D 59 34 22 56 46 46 <br /> B 85 50 31 81 66 66 <br /> 120 mph 150 mph C '61 36 22• 58 '47 47 <br /> D 51 30 19 49 40 40 <br /> Notes: <br /> :Spacing Governed by Snow Load <br /> 1.)Values in above.table represent the maximum allowable spacing-in inches.for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.):Maximum allowed standoff capcity=547#(per testing results) <br /> 4:)Includes additional factor of safety of 1.5.for lag pullout capacity <br /> 5.)Values based.on'a,maximum module width of 40 <br /> 6.)Based on Risk Category.II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors-are set to 1.No site specific engineering is included in this table <br /> Snow Load 0-20.psf <br /> Wind S eed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7=10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> B 91 53 33 <br /> 85 mph 110 mph C 65 38 24 61 50 50 <br /> D 55 32 20 52 42 42 <br /> B 83 49 30 <br /> 90-mph 115 mph C 59. 35 22- 56 46 46 <br /> D 50 29 18 47 38 38 <br /> B 70 41 26 54 54 <br /> 100 mph 125 mph C 50 29 18 47 39 39 <br /> D 42___26 15 40 32 32 _ <br /> �- B 56 33 w 20 _ 53 v 43 43 m <br /> 110 mph -140 mph . C 40 23 14 38 31 31 <br /> D -34 19 12 32 26 26 <br /> B 49 28 18 46 37 37 <br /> 120 mph 150 mph C 35 20 12 33 27 27 <br /> D 29 17 10 28 1 22 1 22 <br /> Notes: <br /> —Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for-pullout forces only on EcoFasten Solar.standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)-Maximum allowed standoff capcity.=547#(per testing.results) <br /> 4.),Includes additional factor.of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on.a maximum module length of-70" <br /> 6:)Based on Risk Category 11(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is included in.this table. <br /> www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 8 <br />