Laserfiche WebLink
L`1 <br /> Snow Load 31-40 psf <br /> Modules in Landscape <br /> Wind Speed Exposure 2:12<.Roof Pitch <6:12 7:12<Roof Pitch< 12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone:2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> B 83 �6 59 <br /> 85 mph 110 mph C 83 67 42 <br /> D 8- 56 _ 35__ <br /> 90 mph 115 mph - C 83 61 38 1 <br /> D 51 32 <br /> B 83 45 <br /> 100 mph 125 mph C 6 51 32 <br /> D 74 43 27 •1 <br /> B 83 57 36 <br /> 110 mph 140 mph C 70 41 26 <br /> D 59 34. .22. 46 46 <br /> B 83 50 31- <br /> 120 mph 150 mph C 61 36 22 47 47 <br /> D 51 30 19 49 40 40 <br /> Notes: <br /> ®Spacing Governed by Snow Load <br /> 1.)Values in-above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar.standoff, <br /> however the designer must round down to meet appropriate.rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6:)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.).AII adjustment factors are set to 1.No site specific engineering is included in this table. <br /> Snow Load'31-40 psf <br /> Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10. Category Zone.1 Zone 2 Zone 3 Zone 1 Zone 2 -Zone 3 <br /> B 33 <br /> 85 mph 110 mph C 38 24 <br /> 32_ --__ 20__ <br /> B 49 30 <br /> 90 mph 115 mph C 35 22 <br /> D 29 18 <br /> B 41 26 <br /> 100 mph 125 mph C 29 18 <br /> -D - - 42 --- 26 -_--15- - <br /> B 33 20 <br /> 110 mph 140 mph C 40 23 14 <br /> D 34 .19 12 26 26 <br /> B 49 28 18 <br /> 120 mph 150 mph C 35 20 12 27 27 <br /> D 29 17 10 28 22 22 <br /> Notes: <br /> Spacing.Governed by Snow Load <br /> 1.)Values in above table represent the maximum.allowable spacing in inches for pullout forces only on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing,approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5.for lag pullout capacity <br /> 5.)Values based on a maximum module length of 70" <br /> 6.)Based on Risk Category 11(ASCE 7-10)-structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is included in this table <br /> www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 10 <br />