Laserfiche WebLink
Snow Load 41-50 psf <br /> Modules in Landscape <br /> Wind Speed. Exposure 2:12<Roof Pitch<6:12 7:12<.Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10. Category Zone 1- Zone 2 Zone 3 -Zone 1 Zone:2 Zone 3 <br /> B ' 66 6• 59 <br /> 85.mph 110 mph' C 6 6 42 <br /> D_ 6 56 35 <br /> B liiiiiiiffl6 1111111 54 5 5 <br /> 90 mph -115 mph C 66 61 38 5 <br /> D 66 51 32 <br /> B 6 6• 45 <br /> 100 mph 125 mph C 66 51 32 <br /> D 66 43 27 <br /> B 6 57 36 <br /> 110 mph 140.mph C 6 41 26 <br /> D 59 34_ _ 22 46 46 <br /> 120 mph 150 mph C 61 '36 22• 5 47 47 <br /> D 51 30 19 49 40 40 <br /> Notes: <br /> ®Spacing Governed by Snow Load <br /> 1.)Values in-above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, <br /> however the.designer must round down to meet appropriate rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff capcity=54.7#(per testing:results) <br /> 4:)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is included in this table <br /> Snow Load 41-50 psf <br /> Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> B 33 <br /> 85 mph 110 mph C 38 24 <br /> D 32 20 <br /> B 30 <br /> 90.mph 115 mph C 35 22- <br /> D 29 18 <br /> B 26 <br /> 100 mph 125 mph C 29 18 <br /> -- - --- - - -- -D- — --26 - 15---- <br /> 13 33 20 <br /> 110 mph 140 mph' C 23 14 <br /> D 19 12 <br /> B 28 18 <br /> 120 mph 150 mph C 35 20 12 <br /> D 29 17 10 22 22 <br /> Notes: <br /> —Spacing Governed.by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches:for pullout forces only on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> -4.)Includes additional factor of safety of 1.5 for.lag pullout capacity <br /> 5.)Values based on a maximum module length of 70" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.'No site specific engineering is included in this table <br /> www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 11 <br />