Laserfiche WebLink
Section <br /> # Mechanical Rough-In Inspection Complies? Comments/Assumptions <br /> & Req.ID <br /> C402.2.6 ;Thermally ineffective panel surfaces of;❑Complies :Requirement will be met. <br /> [ME41]3 sensible heating panels have ;❑Does Not <br /> insulation >= R-3.5. <br /> '❑Not Observable <br /> ❑Not Applicable <br /> C403.2.9. HVAC ducts and plenums insulated ',❑Complies Requirement will be met. <br /> 1.1 and sealed according to Florida 1❑Does Not <br /> [ME60]2 ;Section C403.2.9,Table C403.2.9.1. <br /> ,❑Not Observable <br /> ❑Not Applicable <br /> C403.2.9. All ducts, air handlers, filter boxes, ;❑Complies ;Requirement will be met. <br /> 2 I building cavities, mechanical closets E❑Does Not <br /> [ME79]2 I and enclosed support platforms that <br /> ;form the primary air containment ❑Not Observable <br /> passageways for air distribution ;❑Not Applicable <br /> }systems are constructed and erected <br /> in accordance with Table C403.2.9.2 ; <br /> l and with Chapter 6 of the Florida <br /> ;Building Code, Mechanical. Ducts are <br /> be constructed, braced, reinforced <br /> ,and installed to provide structural <br /> strength and durability. All transverse <br /> (joints, longitudinal seams and fitting <br /> I connections are securely fastened in <br /> accordance with the applicable <br /> ;standards of this section. <br /> C403.2.9. ;Duct insulation is protected from ;❑Complies ;Requirement will be met. <br /> 1.2 ;damage but not limited to the E❑Does Not <br /> [ME80]2 ;following: 1. Insulation exposed to <br /> ❑Not Observable; <br /> weather is suitable for outdoor <br /> i service. Cellular foam insulation is ;❑Not Applicable ; <br /> j protected or painted with a coating <br /> ;that is water retardant and provides ; <br /> shielding from solar radiation. 2. <br /> Insulation covering cooling ducts <br /> located outside the conditioned space <br /> a is vapor retardant located outside the I <br /> insulation, all penetrations and joints <br /> of which shall be sealed. <br /> C403.2.9. ;Additional insulation with vapor ;❑Complies ;Requirement will be met. <br /> 1.3 1 barrier is provided where the :❑Does Not <br /> [ME81]2 ;minimum duct insulation requirements: <br /> 'of Section C403.2.9.1.1 are ❑Not Observable <br /> determined to be insufficient to ;❑Not Applicable <br /> prevent condensation. <br /> C403.2.13 I Unenclosed spaces that are heated ;❑Complies ;Requirement will be met. <br /> [ME71]2 use only radiant heat. UDoes Not <br /> j ;❑Not Observable; <br /> ❑Not Applicable <br /> C403.2.3 HVAC equipment efficiency verified. I❑Complies ;See the Mechanical Systems list for values. <br /> [ME55]2 ; ;❑Does Not <br /> ;❑Not Observable <br /> ❑Not Applicable <br /> C403.2.9. 'Ducts, air handlers, filter boxes, ;❑Complies ;Requirement will be met. <br /> 3 ;building cavities, mechanical closets :❑Does Not <br /> [ME10]2 and enclosed support platforms that <br /> ;form the primary air containment ❑Not Observable <br /> passageways for air distribution :❑Not Applicable <br /> ;systems are sealed in accordance with; <br /> {the applicable criteria of this section ; <br /> land Table C403.2.9.2. <br /> 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) <br /> Project Title: Zephyrhills Report date: 01/14/21 <br /> Data filename: U:\2020\2001004 Chipotle-Zephyrhills, FL\calcs\Zephyrhi Hs,FL_Com check.cck Page 9 of 17 <br />