My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1617
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1617
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 11:34:15 AM
Creation date
5/9/2022 11:34:08 AM
Metadata
Fields
Template:
Building Department
Company Name
SF ZEPHYR COMMONS OUTPARCEL LP
Building Department - Doc Type
Permit
Permit #
21-1617
Building Department - Name
SF ZEPHYR COMMONS OUTPARCEL LP
Address
7642 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section <br /> # Mechanical Rough-in Inspection Complies? Comments/Assumptions <br /> & Req.ID F <br /> C403.2.9. ;Cavities in framed spaces are not ;❑Complies :Requirement will be met. <br /> 4 {used to deliver air from or return air to;❑Does Not <br /> [ME78]2 ;the conditioning system unless they ❑Not Observable <br /> ;contain an air duct insert which is , <br /> insulated in accordance with Section ;❑Not Applicable ; <br /> C403.2.9.1 and constructed and <br /> +sealed in accordance with the <br /> requirements of Section C403.2.9.2 ; <br /> appropriate for the duct materials <br /> ;used. ; <br /> C403.2.9. 'Air distribution systems are sized and ;❑Complies ;Requirement will be met. <br /> 5 designed in accordance with ❑Does Not <br /> [ME76]2 ;recognized engineering standards. <br /> Refer to section details. ❑Not Observable; <br /> ;❑Not Applicable ; <br /> C403.2.9. jAir-handling units not installed in ;❑Complies ;Exception: Requirement does not apply. <br /> 6 lattics of commercial buildings. ;❑Does Not <br /> [ME77]z 1 <br /> I ,❑Not Observable <br /> ( ;❑Not Applicable <br /> C403.2.4. Fault detection and diagnostics ;❑Complies ;Requirement will be met. <br /> 7 !installed with air-cooled unitary DX !❑Does Not <br /> [ME113]2 i units having economizers. ; <br /> :[:]Not Observable <br /> ❑Not Applicable <br /> C403.2.4. Fault detection and diagnostics ;❑Complies ;Requirement will be met. <br /> 7 installed with air-cooled unitary DX U❑Does Not <br /> [ME113]2 'units having economizers. <br /> ❑Not Observable: <br /> ❑Not Applicable <br /> C408.2.2. ;Air system balancing accomplished in ;❑Complies ;Requirement will be met. <br /> 1 )a manner to first minimize throttling :❑Does Not <br /> [ME53]3 ;losses,then for fans with fan system ; <br /> power greater than 1 hp,fan speeds ❑Not Observable <br /> shall be adjusted to meet design flow ;❑Not Applicable <br /> ;conditions. Balancing procedures shall <br /> be in accordance with NEBB ; <br /> Procedural Standards, the AABC, ; <br /> National Standards, or equivalent <br /> procedures. <br /> C403.2.6. ;Demand control ventilation provided ;❑Complies ;Exception: Systems with design outdoor air of less than 1200 <br /> 1 :for spaces >500 ft2 and >25 ;❑Does Not cfm. <br /> [ME59]1 ;people/1000 ft2 occupant density and ; <br /> ;served by systems with air side I❑Not Observable <br /> economizer, auto modulating outside ;❑Not Applicable <br /> ;air damper control, or design airflow <br /> >3,000 cfm. <br /> C403.2.6. Enclosed parking garage ventilation ;❑Complies ;Exception: Requirement does not apply. <br /> 2 has automatic contaminant detection ;❑Does Not <br /> [ME115]3 and capacity to stage or modulate ; l <br /> ;fans to 50%or less of design capacity. ;❑Not Observable <br /> ;❑Not Applicable ; <br /> C403.2.7 Exhaust air energy recovery on ;❑Complies ;Requirement will be met. <br /> [ME57]1 systems meeting Table C403.2.7(1) :❑Does Not <br /> land C403.2.7(2). ENot Observable' <br /> ❑Not Applicable <br /> C403.2.8 ;Kitchen exhaust systems comply with ;❑Complies ;.Requirement will be met. <br /> [ME116]3 replacement air and conditioned !❑Does Not <br /> supply air limitations, and satisfy hood <br /> rating requirements and maximum ❑Not Observable <br /> exhaust rate criteria. ;❑Not Applicable <br /> 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 Low Impact(Tier 3) <br /> Project Title: Zephyrhills Report date: 01/14/21 <br /> Data filename: U:\2020\2001004 Chipotle-Zephyrhills, FL\calcs\Zephyrhills,FL Comcheck.cck Page 10 of 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.