My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1629
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1629
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 11:41:55 AM
Creation date
5/9/2022 11:41:52 AM
Metadata
Fields
Template:
Building Department
Company Name
MARY HOUSE E LIV TRUST
Building Department - Doc Type
Permit
Permit #
21-16229
Building Department - Name
MARY HOUSE E LIV TRUST
Address
37448 BLUEBERRY CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OMEMO I etc. <br /> ROOFING COMPONENT EVALUATION: <br /> SCOPE:I. <br /> Product Category: Roofing <br /> Sub-Category: Underlayment <br /> Compliance Statement: RhinoRoof® GRN, as produced by Owens Corning Roofing and Asphalt, LLC, has <br /> demonstrated compliance with the following sections of the 7eh Edition (2020) Florida Building Code through <br /> testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and <br /> Limitations/Conditions of Use set forth herein. <br /> 2. STANDARDS: <br /> Section Property Standard Year <br /> 1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015 <br /> /R905.1.1,R905.2.8.2 <br /> 3. REFERENCES: <br /> Entity Examination Reference Date <br /> PRI(TST5878) ASTM D1970 OCF-293-02-03 12/20/2017 <br /> PRI(TST5878) ASTM D1970 OCF-253-02-02 12/21/2017 <br /> Owens Corning Quality Control Declaration 07/15/2020 <br /> PRI(QUA9110) Quality Control Service Confirmation 05/05/2020 <br /> PRI(QUA9110) Quality Control Florida BCIS Current <br /> 4. PRODUCT DESCRIPTION: <br /> Product Material Standard Plant(s) Description <br /> RhinoRoof®GRN ASTM D1970(Table 1)' Brentwood, NN Granule-surfaced,self- <br /> Houston,TX adhering, roof underlayment <br /> 5,. LIMITATIONS: <br /> 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer <br /> of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting <br /> or design guidance unless retained specifically for that purpose. <br /> 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- <br /> Dade Counties). <br /> 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in <br /> accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. <br /> 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and <br /> limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations <br /> concerning the use of foam plastic insulation. <br /> 5.5 RhinoRoof GRN may be used with any prepared roof cover where the product is specifically referenced within FBC <br /> approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based <br /> on this evaluation combined with supporting data for the prepared roof covering. <br /> 1 Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance <br /> of RhinoRoof GRN. <br /> MEMO ETC,LLC Evaluation Report 3m-OC-20-FBCER.01-R3 <br /> Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL32344-R1 <br /> Owens Corning RhinoRoof®GRN Revision 1:12/10/2020 <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.