OMEMO I etc. <br /> 5.6 Allowable Roof Covers: <br /> TABLE 1: ROOF COVER OPTIONS <br /> FBC Section: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&1507.9 <br /> Clay and Concrete TILE Metal Wood <br /> Underlayment Asphalt Slate or Slate- <br /> Mechanical Adhesive- Panels Shingles' Type Shingles Attach Set g g Shingles Shakes <br /> Yes <br /> RhinoRoof®GRN Yes No No No No Yes <br /> (joint strips,1507.1.1.3/ <br /> R905.1.1.3) <br /> 5.7 Allowable Substrates: <br /> TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS <br /> Substrates(designed to meet wind loads for project) <br /> Underlayment Application <br /> Type Primer Material(s) <br /> RhinoRoof®GRN self-adhering Deck/sheathing None Plywood <br /> 5.8 Attachment Limitations: <br /> For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with <br /> the manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets-not <br /> less than FBC 1507.1.1 or R905.1.1. <br /> 5.9 Exposure Limitations: <br /> TABLE 3: EXPOSURE LIMITATIONS <br /> Underlayment Prepared Roof Cover Installation Type Maximum Exposure(days) <br /> RhinoRoof®GRN Mechanically attached 30 <br /> 6. INSTALLATION: <br /> 6.1 RhinoRoof GRN shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published <br /> installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. <br /> 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to <br /> remove any dust and debris prior to application,and prime the substrate(if applicable). <br /> 6.3 RhinoRoof®GRN: <br /> Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970) in <br /> FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering <br /> to be installed,and the manufacturer's installation instructions. <br /> 7. BUILDING PERMIT REQUIREMENTS: <br /> As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this <br /> product. <br /> 8. MANUFACTURING PLANTS: <br /> Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 611320-3 CIA requirements. Refer <br /> to Section 4 herein for products and production locations having met codified material standards. <br /> 9. QUALITY ASSURANCE ENTITY: <br /> PRI Construction Materials Technologies, LLC—QUA9110;(813)621-5777;bwilson@pricmt.com <br /> -END OF EVALUATION REPORT- <br /> MEMO ETC,LLC Evaluation Report 3m-OC-20-FBCER.01-Ri <br /> Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL32344-RI <br /> Owens Corning RhinoRoof®GRN Revision 1:12/10/2020 <br /> Page 3 of 3 <br />