My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1630
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1630
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 11:43:10 AM
Creation date
5/9/2022 11:43:07 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1630
Building Department - Name
OTERO,JUAN & ELSIE
Address
37420 CASTLEBERRY AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONEMOletc. <br /> TABLE 1:ASPHALT SHINGLE COMPONENTS <br /> Type Product Plant(s) Material' Description. <br /> Standard <br /> Berkshire'Hip and Ridge MN <br /> Shingles with Sealant <br /> Hip and DuraRidge®Hip and Ridge <br /> Ridge Shingles with Sealant MN ASTM D3462 fiberglass reinforced,hip and ridge <br /> Shingles ProEdge® GA,CA,OH,OR asphalt roof shingles <br /> WeatherGuard®HP Hip and TN <br /> Ridge Shingles <br /> LIMITATIONS:S. <br /> 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer <br /> of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting <br /> or design guidance unless retained specifically for that purpose. <br /> 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami- <br /> Dade Counties). <br /> 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in <br /> accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. <br /> 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and <br /> limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations <br /> concerning the use of foam plastic insulation. <br /> 5_5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications <br /> TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES <br /> Product FBC Table 1507.2.7.1 or R905.2.6.1 <br /> Supreme* <br /> Berkshire* <br /> Duration®Premium <br /> Duration'Premium COOL <br /> TruDefinition'Duration' ASTM D3161(F)&ASTM D7158(H) <br /> TruDefinition°Duration*Designer Color Collection <br /> Oakridge' <br /> TruDefinition°Oakridge° <br /> WeatherGuard°HP <br /> 5.5.1 Classification by ASTM D7158: <br /> ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations <br /> by a qualified design professional are required for conditions outside these limitations. Contact the shingle <br /> manufacturer for data specific to each shingle. <br /> MEMO ETC,LLC Evaluation Report 037940.02.12-1131 <br /> Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116 <br /> Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 <br /> Page 3 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.