1 <br /> I, <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E...shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O:W. use permit: A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All.property markers shall be uncovered.and marked at time of first inspection. <br /> 8:. All A.-D.A.requirements shall be met: <br /> 9. No electric,plumbing;mechanical, or framing shall be:covered without an inspection and <br /> . <br /> approval first. <br /> 10. All Garages shall comply with section-R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject.to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the R.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308A. <br /> 14. Return air in all bedrooms. F.B.C. M1'620.4 <br /> 15. Smoke.detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance.with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. `-`Green gypsum.board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />